  • Operating pressure range :4–20 cm H2O
  • Sound pressure level :26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009(CPAP mode)
  • 90W power supply unit
  • Input range :100–240V, 50–60Hz, 57VA(typical power consumption); >108VA(maximum power consumption)
  • Operating  : temperature humidity altitude:+5°C to +35°C 10–95%, non-condensing Sea level to 2,591 m
  • Temperature humidity  :-20°C to +60°C ,5–95% relative humidity, non-condensing
  • Standard air filter  : Polyester non-woven fiber
  • Tubing  : SlimLine (15 mm); Standard (19 mm)
  • Air outlet 22 mm air outlet complies with ISO 5356-1:2004 IEC 60601-1: 2006classification

Do you want to make Product
Inquiry

Make Inquiry

19 People watching this product now!
  • Check Our Stores
  • Contact Us For More Information
  • Download the Product Catalog
  • Visit Our location

Description

Product Specification

Brand ResMed
Model Air Start 10
Pressure Range (cm H2O) 4 – 20
Sound/Noise Level (db) 26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)
Weight (Kg/gm) 1106 gm
Dimensions 116 x 205 x 150 mm
Filters Type Standard Air Filter Polyester non-woven fibre

Product Description

 

  • The AirStart 10 APAP therapy device is designed to be intuitive and easy-to-use. With no complicated menus or settings to navigate, patients can simply plug in the device and press Start.
  • Excellent value. With out-of-the-box simplicity, AirStart 10 devices give you excellent value on the latest technology platform.
  • Built-in humidification
    Heated humidification may help reduce the common side effects of therapy, such as nasal congestion and a dry nose or throat, to deliver even more comfort during the night.
  • Every AirStart 10 therapy device comes with a built-in HumidAir™ humidifier, so your patients can enjoy all the benefits of humidification in one out-of-the-box solution. The humidifier tub is also intuitive to use and manage making humidification easy and accessible for more patients.
  • Operating pressure range :4–20 cm H2O
  • Sound pressure level :26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009(CPAP mode)
  • 90W power supply unit
  • Input range :100–240V, 50–60Hz, 57VA(typical power consumption); >108VA(maximum power consumption)
  • Operating  : temperature humidity altitude:+5°C to +35°C 10–95%, non-condensing Sea level to 2,591 m
  • Temperature humidity  :-20°C to +60°C ,5–95% relative humidity, non-condensing
  • Standard air filter  : Polyester non-woven fiber
  • Tubing  : SlimLine (15 mm); Standard (19 mm)
  • Air outlet 22 mm air outlet complies with ISO 5356-1:2004 IEC 60601-1: 2006classification

Specification

Overview

Features

General