CPAP
Details :
- Operating pressure range :4–20 cm H2O
- Sound pressure level :26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009(CPAP mode)
- 90W power supply unit
- Input range :100–240V, 50–60Hz, 57VA(typical power consumption); >108VA(maximum power consumption)
- Operating : temperature humidity altitude:+5°C to +35°C 10–95%, non-condensing Sea level to 2,591 m
- Temperature humidity :-20°C to +60°C ,5–95% relative humidity, non-condensing
- Standard air filter : Polyester non-woven fiber
- Tubing : SlimLine (15 mm); Standard (19 mm)
- Air outlet 22 mm air outlet complies with ISO 5356-1:2004 IEC 60601-1: 2006classification
Do you want to make Product
Inquiry
15
People watching this product now!
Description
Product Specification
Brand | ResMed |
Model | Air Start 10 |
Pressure Range (cm H2O) | 4 – 20 |
Sound/Noise Level (db) | 26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode) |
Weight (Kg/gm) | 1106 gm |
Dimensions | 116 x 205 x 150 mm |
Filters Type | Standard Air Filter Polyester non-woven fibre |
Product Description
Â
- The AirStart 10 APAP therapy device is designed to be intuitive and easy-to-use. With no complicated menus or settings to navigate, patients can simply plug in the device and press Start.
- Excellent value. With out-of-the-box simplicity, AirStart 10 devices give you excellent value on the latest technology platform.
- Built-in humidification
Heated humidification may help reduce the common side effects of therapy, such as nasal congestion and a dry nose or throat, to deliver even more comfort during the night. - Every AirStart 10 therapy device comes with a built-in HumidAirâ„¢ humidifier, so your patients can enjoy all the benefits of humidification in one out-of-the-box solution. The humidifier tub is also intuitive to use and manage making humidification easy and accessible for more patients.
- Operating pressure range :4–20 cm H2O
- Sound pressure level :26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009(CPAP mode)
- 90W power supply unit
- Input range :100–240V, 50–60Hz, 57VA(typical power consumption); >108VA(maximum power consumption)
- Operating : temperature humidity altitude:+5°C to +35°C 10–95%, non-condensing Sea level to 2,591 m
- Temperature humidity :-20°C to +60°C ,5–95% relative humidity, non-condensing
- Standard air filter : Polyester non-woven fiber
- Tubing : SlimLine (15 mm); Standard (19 mm)
- Air outlet 22 mm air outlet complies with ISO 5356-1:2004 IEC 60601-1: 2006classification