Horizontal Autoclave Electric
Features :
- The inner/outer chamber, steam jacket and boiler are made of heavy gauge SS with leak proof argon arc welding.
- Steam boiler is fitted with water level indicator, pressure gauge, low water cut off device and automatic pressure control devices. Fitted with safety valve as a safety device.
- Drain valve is fitted at the side bottom for easy draining/clearing.
- Two separate valves are provided for evacuating steam from inner chamber and jacket as and when desired.
- Sterilization cycle is controlled by single point multiport valve.
- An automatic vacuum breaker is fitted to all units as a standard accessory in order to break vacuum in case of steam condensation.
- The flanged immersion type heating element made from a very high grade material provide fast formation of pressure in the system and are protected through a electric low water level cut off device to work on 220/230 or 440 volts, 3 phase, 50 Hz AC supply.
Do you want to make Product
Inquiry
16
People watching this product now!
Description
Product Specification
| Usage/Application | Dental |
| Chamber Volume | 78L – 221 L |
| Material | Stainless Steel |
| Mount Type | Floor Mounted Autoclave |
| Capacity | 78 – 221 Liter |
| Insulation Wall | Triple Wall |
| Temperature Range | 121-134 degree |
| Model Name/Number | TAI-909 |
| Pressure Range | 15 – 25 psi |
| Automation Grade | Fully Automatic |
| Power Consumption | 6 – 12 KW |
| Warranty | 1 Year |
| Brand | Thymol |
| No. Of Trays | 1 Tray |
| Voltage | 230 – 440 V |
| Loading Type | Front Loading Autoclave |
| Door Type | Radial Locking |
| Is It Rust Proof | Rust Proof |
| Frequency | 50 Hz |
| Phase | Three Phase |
| Pressure Gauge | 0.2.1 kgf/cm2 |
| Minimum Order Quantity | 1 |
Product Description
Features :
- The inner/outer chamber, steam jacket and boiler are made of heavy gauge SS with leak proof argon arc welding.
- Steam boiler is fitted with water level indicator, pressure gauge, low water cut off device and automatic pressure control devices. Fitted with safety valve as a safety device.
- Drain valve is fitted at the side bottom for easy draining/clearing.
- Two separate valves are provided for evacuating steam from inner chamber and jacket as and when desired.
- Sterilization cycle is controlled by single point multiport valve.
- An automatic vacuum breaker is fitted to all units as a standard accessory in order to break vacuum in case of steam condensation.
- The flanged immersion type heating element made from a very high grade material provide fast formation of pressure in the system and are protected through a electric low water level cut off device to work on 220/230 or 440 volts, 3 phase, 50 Hz AC supply.
Specification:
| Model | 16×24 | 16×36 | 16×48 | 20×36 | 20×48 |
| Inner Dimension (mm) | 400×600 | 400×900 | 400×1200 | 500×900 | 500×1200 |
| Capacity | 78 Litres | 115 Litres | 162 Litres | 165 Litres | 221 Litres |
| Load | 6 KW | 9 KW | 12 KW | 12 KW | 12 KW |
Technical Specification:
- Gasket: Made of joint less silicon rubber.
- Exhaust pressure: Manual through the exhaust valve
- Sterilizing pressure: 1.2 to 1.5 kgf/cm2 (15 to 20 psi) at 121oC
- Operating pressure: from 15 psi to 20 psi
- Pressure gauge: 0.2.1 kgf/cm2 (30 psi)
Including:
- Automatic pressure cut off switch
- Digital temperature indicator cum controller
- Vacuum breaker
- Water level indicator
- Automatic self locking system
- Automatic low water cut off switch
- Moisture trap
- Fully automatic system with HMI PLC based autoclave with data logger digital pressure indicator cum controller, digital temperature controlled system with vacuum drying system.